F-gas: HFC phase-down step goes ahead on 1 January 2027 as Defra holds back wider reform

Defra will not change the GB HFC phase-down in 2026, so the quota falls from 31% to 24% on 1 January 2027. What it means for air conditioning and VRF.

Row of VRF air conditioning condensers on steel frames on a central London office roof

The next step in Great Britain’s HFC phase-down will go ahead as already set out in law. In May 2026, Defra said it had looked at the 137 responses to its consultation on a tighter schedule and concluded that more work was needed. It also said it would not legislate in 2026 to change the phase-down steps that take effect from 1 January 2027.

That leaves the step already written into the GB F-gas Regulation in place. The quota of HFCs that can be placed on the market falls from 31% of the baseline (2024 to 2026) to 24% for 2027 to 2029, and then to 21% from 2030. The baseline is the average quantity placed on the market between 2015 and 2019.

What the consultation proposed

The consultation, which ran from November to December 2025, proposed a faster and deeper phase-down than the current law, with changes starting in 2027. Defra says it remains committed to reform and plans to publish a summary of responses and next steps. For now, that proposal has no date and is not law.

Why it still matters on site

The quota applies to producers and importers of bulk HFCs, not directly to building owners. Nobody is told to rip out a working system on a set date. The effect is indirect but real:

  • Supply of high-GWP refrigerants keeps tightening. Gases such as R410A and R404A draw more heavily on the quota, so availability and price are more exposed than for lower-GWP alternatives.
  • Equipment choice shifts. Manufacturers have largely moved split systems to R32, and lower-GWP options are growing across VRF, chillers and heat pumps.
  • Existing systems still need looking after. Leak checking, record keeping and qualified handling rules are unchanged. A leaking older system becomes more expensive to keep topped up.

What London projects should do

On office fit-outs and refurbishments across London, the questions we are asked most often are whether to keep or replace an existing VRF system, and what to specify for a new one. Our practical advice:

  1. Record what is installed now. Note the refrigerant type, charge, age and leak history for each system. That makes the keep-or-replace decision much easier.
  2. Specify for the life of the equipment. A new system will be running well into the 2030s. Choose a refrigerant that will still be serviceable throughout.
  3. Design for a small charge and easy leak detection. Short, well-supported pipe runs, accessible joints and leak detection where the regulations or the room volume call for it are worth doing.
  4. Look at heat recovery and heat pumps together. On many London buildings, heat recovery VRF or an air-to-water heat pump with fan coils is a serious option alongside a like-for-like replacement.

If you are comparing system types, our guide to VRF vs split system choices explains the trade-offs for offices. Our commercial air conditioning page sets out how we design, install and commission systems. For whole-building heating, cooling and ventilation, see HVAC installation in London.

Replacing or extending an air conditioning system? We can survey what is installed and recommend options that will stay serviceable. See our air conditioning installation service.