Air conditioning · London & Home Counties

Commercial air conditioning design and installation in London

VRF, VRV, split and multi-split systems sized from heat-gain calculations, coordinated with the fabric and the other services, then installed and commissioned.

Rooftop VRF air conditioning units with the London skyline behind

Cooling that has somewhere to live

  • Plant that fits the roof or the yard

    Outdoor units, pipe routes and structural loads agreed in the model, including screening and access for maintenance.

  • Indoor units that fit the ceiling

    Cassettes, ducted units and wall units coordinated with lights, ducts and sprinklers.

  • One point of responsibility

    Design, installation and commissioning can be delivered by one team.

  • London & Home Counties

    Greater London plus Surrey, Kent, Essex, Hertfordshire, Berkshire and Buckinghamshire.

What we design and install

Air conditioning systems for offices, retail and homes

The right system depends on the number of rooms, the hours of use, and how much outdoor space the building can spare.

VRF and VRV

Multi-zone heat-recovery or heat-pump systems for offices, hotels and larger homes, with long pipe runs designed in the model.

Split and multi-split

Single and multi-indoor-unit systems for smaller suites, server rooms and individual dwellings.

Cassette, ducted and wall units

Indoor unit type chosen for the ceiling, the noise limit and the way the room is used.

Chilled water

Fan coil units and small chiller plant where a water-based system is the better fit.

Heat-gain calculations

Cooling loads from fabric, glass, occupancy, lighting and equipment, not a rule of thumb.

Refrigerant pipework

Pipe routes, branches and isolation shown in the model, with lengths and rises checked against the manufacturer's limits.

Condensate

Gravity routes where possible, pumped routes where not, coordinated with the drainage.

Controls

Local controllers, central controllers and links to a building management system.

Testing and commissioning

System set-up, refrigerant checks, controls demonstration and handover records.

Exposed ventilation ductwork and ceiling cassette air conditioning in a London office
Designed in BIM

Outdoor units, pipework and indoor units in one model

London roofs are crowded, and many façades sit in conservation areas that will not accept a casual condenser. We model the outdoor plant, the pipe risers and the indoor units with the architect's elevations and the structural loads.

Inside the building, a cassette that looks fine on a 2D plan often collides with a duct, a beam or a smoke detector. Coordinating the indoor units in Revit avoids that conversation on a finished ceiling.

If the cooling is part of a wider HVAC or fit-out package, we design it with the ventilation and heating so the systems do not fight each other.

  • Heat-gain calculations for each space
  • Pipe length, rise and branch checks before equipment is ordered
  • Roof, wall and acoustic constraints agreed early
  • Electrical supplies and condensate included in the same model
  • Commissioning and controls handover
Process

From load calculation to a running system

  1. Survey

    Building fabric, outdoor plant space, electrical capacity and neighbours.

  2. Design

    Loads, system selection and schematic pipe routes.

  3. Model

    Indoor and outdoor units coordinated in Revit.

  4. Install

    Placement, pipework, electrics, condensate and controls.

  5. Commission

    Set-up, demonstration and handover records.

Commercial plant room with air handling unit, ductwork and insulated pipework
Related services

Air conditioning with ventilation, heating and power

Cooling is rarely a stand-alone decision. We also design and install the ventilation, heating and electrical supplies that make the system work, across London and the Home Counties.

Related pages

Sectors

FAQ

Questions

Which air conditioning systems do you work with?

VRF and VRV heat-recovery and heat-pump systems, split and multi-split systems, ceiling cassettes, ducted units and chilled-water fan coils, sized from heat-gain calculations.

Can you install in a listed or conservation-area building?

Yes, with a survey and, where needed, a design that keeps outdoor plant out of sensitive elevations. We will tell you if a proposed location is unlikely to be acceptable.

Do you only install, or do you also design?

We design, install and commission, or we can provide the design and model for another installer.

Will you coordinate with the rest of the ceiling?

Yes. Indoor units, pipes and condensate are modelled with ducts, lights, sprinklers and the structure.

What happens at handover?

The system is set up, demonstrated and handed over with records, controls settings and O&M information.

Contact

Planning air conditioning for a London building?

Call us, or leave your phone number and an engineer will call you back to talk through the rooms, the outdoor plant space and the next steps.

  • London and the Home Counties
  • Design-only, BIM-only or full design and installation
  • Revit, IFC and Navisworks deliverables

Request a call back