Electrical · London & Home Counties

Electrical design and installation in London

Power, lighting, containment and distribution designed to BS 7671, coordinated in the same Revit model as the mechanical services, then installed and tested.

Engineer terminating cables in an electrical distribution board

Electrical design that leaves room for everything else

  • Containment in the model, not as an afterthought

    Trays, baskets and trunking coordinated with ducts, pipes and the structure.

  • Designed to BS 7671

    Calculations, protective device selection and a design that can be installed and certified.

  • One point of responsibility

    Design, installation and commissioning can be delivered by one team.

  • London & Home Counties

    Greater London plus Surrey, Kent, Essex, Hertfordshire, Berkshire and Buckinghamshire.

What we design and install

Electrical systems for commercial and residential buildings

From a lighting and small-power fit-out to a full distribution design for a building, coordinated with the mechanical plant it has to serve.

Distribution

Incoming supplies, switchgear, distribution boards and sub-mains, with space and access modelled.

Small power

Socket layouts, specialist supplies and containment, coordinated with furniture and partitions.

Lighting

Luminaire layouts, switching, dimming and emergency lighting, worked out with the ceiling design.

Containment

Cable tray, basket, trunking and risers, sized and routed in the model.

Mechanical supplies

Power and controls wiring for HVAC, heat pumps, pumps and air handling plant, designed with the mechanical team.

Earthing and bonding

Designed with the incoming arrangement and the building's metallic services.

Life-safety supplies

Where the fire strategy requires them, coordinated with the fire alarm and the mechanical smoke systems.

Metering and landlord distribution

Tenant and landlord splits on mixed-use and residential blocks.

Inspection and testing

Installation, inspection and testing, with records issued at handover.

Coordinated Revit model of ductwork, pipework and cable trays in an office ceiling void
Designed in BIM

Cable routes that share the void without winning every clash

Electrical containment is often drawn last and then expected to find a way through. We model it with the ducts and pipes so the tray does not block a damper, and a distribution board is not left without a door swing.

In London fit-outs the ceiling is a negotiation between lighting, sprinklers, cassettes, ducts and services crossings. A coordinated electrical model is how the lighting layout you approved is the one that can actually be installed.

We also design the supplies that the mechanical plant depends on, so an outdoor heat pump or a roof-top VRF system is not left waiting for a feeder that was never allowed for.

  • Design to BS 7671, with calculations documented
  • Containment and board locations proved in 3D
  • Coordination with HVAC, public health and low voltage systems
  • Survey of existing supplies before we commit to a design
  • Inspection, testing and handover records
Process

From incoming supply to a tested installation

  1. Survey

    Existing supply, boards, containment and the mechanical loads we have to serve.

  2. Design

    Distribution, lighting, small power and calculations to BS 7671.

  3. Model

    Containment, boards and equipment coordinated in Revit.

  4. Install

    Containment, cabling, boards, lighting and accessories, to the model.

  5. Test

    Inspection, testing, certification records and as-built information.

Comms cabinet with neatly patched structured data cabling
Related services

Electrical with low voltage, HVAC and BIM

Fire alarm, data cabling and access control are designed in the same model. So are the supplies to air conditioning, ventilation and heat pumps. We can deliver those packages together.

Related pages

Sectors

FAQ

Questions

Do you design to BS 7671?

Yes. Distribution, protective devices, cable sizing and the installation itself are designed and carried out with BS 7671 in mind, with calculations and test records kept.

Can you work on an existing building's supply?

Yes. We survey the incoming arrangement and the existing boards first, and we will tell you if the supply looks short of what the new loads require.

Do you also do fire alarm and data cabling?

Yes. Those are covered on our low voltage systems page, and they are coordinated in the same model as the power and lighting.

Will containment be shown in the BIM model?

Yes. Tray, basket, trunking and board locations are modelled and clash-checked with the mechanical services.

What do we get at handover?

Inspection and test records, as-built drawings or a model, and O&M information for the installed equipment.

Contact

Planning electrical work in London?

Call us, or leave your phone number and an engineer will call you back to talk through the building, the incoming supply and the next steps.

  • London and the Home Counties
  • Design-only, BIM-only or full design and installation
  • Revit, IFC and Navisworks deliverables

Request a call back