Fire alarm, data cabling and low voltage systems in London
Fire alarm, structured cabling, access control, CCTV and door entry designed in the same Revit model as the mechanical and electrical services, then installed and tested.

Low voltage systems that are part of the building, not an overlay
Devices in the coordinated ceiling
Detectors, cameras, access readers and data outlets placed with lights, sprinklers and air terminals.
Containment shared intelligently
Cabling routes modelled with power containment so the comms tray is not an afterthought.
One point of responsibility
Design, installation and commissioning can be delivered by one team.
London & Home Counties
Greater London plus Surrey, Kent, Essex, Hertfordshire, Berkshire and Buckinghamshire.
Life safety, communications and security systems
The exact package depends on the building and the fire strategy. These are the systems we most often design, coordinate and install.
Fire detection and alarm
System category and device locations developed with the fire strategy, with sounders, interfaces and cause-and-effect considered in the design.
Structured cabling
Horizontal and backbone cabling, patching, cabinets and containment, designed with the comms room and the floor layout.
Access control and door entry
Readers, locks, power supplies and door interfaces, coordinated with ironmongery and the fire alarm.
CCTV
Camera positions, coverage, recording and cable routes, agreed with the way the building is used.
Disabled refuge and alarm systems
Where the building requires them, designed with the fire strategy and the electrical supplies.
TV and satellite distribution
On residential and mixed-use buildings, designed with the risers and the apartment layouts.
Comms rooms and cabinets
Heat, power, containment and space for the cabinet modelled, not left as a leftover cupboard.
Interfaces with mechanical plant
Fire-alarm signals to plant, smoke dampers and smoke-control systems coordinated in the same model.
Testing and handover
System testing, demonstration and as-built information, including cause-and-effect records where they apply.

A fire alarm device is also a point in the ceiling void
Low voltage design often arrives as a symbol on a plan. On site it becomes a base, a back box, a cable and a bit of ceiling that also has to hold a light and a sprinkler. We model the devices and their containment so that conflict is resolved before the ceiling grid goes in.
Fire-alarm interfaces with mechanical plant are another place where packages usually meet too late. If a damper or a smoke system has to respond to the alarm, that relationship is designed into the model and the cause-and-effect, not discovered at commissioning.
For data and security, the comms cabinet needs power, cooling and a cable route that does not block the plant. That is why we treat low voltage as part of the MEP appointment, not a separate specialist who arrives after the risers are full.
- Device locations coordinated with the ceiling and the fire strategy
- Cable routes and cabinets modelled with power and mechanical plant
- Interfaces between fire alarm and mechanical systems agreed early
- Survey of existing systems on refurbishment work
- Testing, demonstration and as-built records
From strategy to a tested system
Brief
Fire strategy, security brief, data requirements and a survey of anything already in the building.
Design
System type, device layouts, cabinet locations and schematics.
Model
Devices and containment coordinated in Revit with the other services.
Install
Cabling, devices, cabinets and interfaces, to the model.
Test
System testing, demonstration and handover records.

Low voltage with electrical design and BIM
Power, containment and the mechanical plant all have to work with these systems. We design and install them as one coordinated package when you need that.
Related pages
Sectors
Questions
Which low voltage systems do you cover?
Fire detection and alarm, structured data cabling, access control, door entry, CCTV, and associated systems such as disabled refuge where the building requires them.
Do you design the fire alarm to the fire strategy?
Yes. Device types, coverage and interfaces are developed with the fire strategy for the building, and coordinated with the mechanical and electrical packages.
Can these systems be included in the Revit model?
Yes. That is the usual way we design them, so detectors, cameras, cabinets and cable routes are clash-checked with ducts, lights and sprinklers.
Do you only install, or also design?
We design, install and test, or we can provide a coordinated design and model for another installer.
What do we get at handover?
Test records, as-built drawings or a model, device schedules, and cause-and-effect or configuration information where it applies.
Planning fire alarm, data or security systems?
Call us, or leave your phone number and an engineer will call you back to talk through the building, the fire strategy and the next steps.
- London and the Home Counties
- Design-only, BIM-only or full design and installation
- Revit, IFC and Navisworks deliverables