Electrical design and installation in London
Power, lighting, containment and distribution designed to BS 7671, coordinated in the same Revit model as the mechanical services, then installed and tested.

Electrical design that leaves room for everything else
Containment in the model, not as an afterthought
Trays, baskets and trunking coordinated with ducts, pipes and the structure.
Designed to BS 7671
Calculations, protective device selection and a design that can be installed and certified.
One point of responsibility
Design, installation and commissioning can be delivered by one team.
London & Home Counties
Greater London plus Surrey, Kent, Essex, Hertfordshire, Berkshire and Buckinghamshire.
Electrical systems for commercial and residential buildings
From a lighting and small-power fit-out to a full distribution design for a building, coordinated with the mechanical plant it has to serve.
Distribution
Incoming supplies, switchgear, distribution boards and sub-mains, with space and access modelled.
Small power
Socket layouts, specialist supplies and containment, coordinated with furniture and partitions.
Lighting
Luminaire layouts, switching, dimming and emergency lighting, worked out with the ceiling design.
Containment
Cable tray, basket, trunking and risers, sized and routed in the model.
Mechanical supplies
Power and controls wiring for HVAC, heat pumps, pumps and air handling plant, designed with the mechanical team.
Earthing and bonding
Designed with the incoming arrangement and the building's metallic services.
Life-safety supplies
Where the fire strategy requires them, coordinated with the fire alarm and the mechanical smoke systems.
Metering and landlord distribution
Tenant and landlord splits on mixed-use and residential blocks.
Inspection and testing
Installation, inspection and testing, with records issued at handover.

Cable routes that share the void without winning every clash
Electrical containment is often drawn last and then expected to find a way through. We model it with the ducts and pipes so the tray does not block a damper, and a distribution board is not left without a door swing.
In London fit-outs the ceiling is a negotiation between lighting, sprinklers, cassettes, ducts and services crossings. A coordinated electrical model is how the lighting layout you approved is the one that can actually be installed.
We also design the supplies that the mechanical plant depends on, so an outdoor heat pump or a roof-top VRF system is not left waiting for a feeder that was never allowed for.
- Design to BS 7671, with calculations documented
- Containment and board locations proved in 3D
- Coordination with HVAC, public health and low voltage systems
- Survey of existing supplies before we commit to a design
- Inspection, testing and handover records
From incoming supply to a tested installation
Survey
Existing supply, boards, containment and the mechanical loads we have to serve.
Design
Distribution, lighting, small power and calculations to BS 7671.
Model
Containment, boards and equipment coordinated in Revit.
Install
Containment, cabling, boards, lighting and accessories, to the model.
Test
Inspection, testing, certification records and as-built information.

Electrical with low voltage, HVAC and BIM
Fire alarm, data cabling and access control are designed in the same model. So are the supplies to air conditioning, ventilation and heat pumps. We can deliver those packages together.
Related pages
Sectors
Questions
Do you design to BS 7671?
Yes. Distribution, protective devices, cable sizing and the installation itself are designed and carried out with BS 7671 in mind, with calculations and test records kept.
Can you work on an existing building's supply?
Yes. We survey the incoming arrangement and the existing boards first, and we will tell you if the supply looks short of what the new loads require.
Do you also do fire alarm and data cabling?
Yes. Those are covered on our low voltage systems page, and they are coordinated in the same model as the power and lighting.
Will containment be shown in the BIM model?
Yes. Tray, basket, trunking and board locations are modelled and clash-checked with the mechanical services.
What do we get at handover?
Inspection and test records, as-built drawings or a model, and O&M information for the installed equipment.
Planning electrical work in London?
Call us, or leave your phone number and an engineer will call you back to talk through the building, the incoming supply and the next steps.
- London and the Home Counties
- Design-only, BIM-only or full design and installation
- Revit, IFC and Navisworks deliverables